Key highlights

  • Flexible control: Controller, limiter or combined controller/limiter options
  • Hazardous area: ATEX/IECEx Ex component-certified BHTC/BHTL for Zone 1/2; BHTLC for Zone 2
  • Wide temperature range: Controls from 0 to 500°C with measurement from -60 to 500°C
  • Heat-trace switching: Up to 30 A for BHTC/BHTL, with BHTLC limited to 22 A
  • Interface options: Dial setpoint, LED, Modbus and Bluetooth options

The Barksdale Kelvin is designed for hazardous area electric trace heating, providing electronic temperature measurement, monitoring, control and limiting within industrial temperature-control systems. BHTC, BHTL and BHTLC configurations provide controller, limiter or combined controller/limiter functions according to the required application.

Typical applications include freeze protection, process temperature control, over-temperature control and viscosity control, where pipework, tanks and other heated equipment must remain within the required temperature range.

Kelvin is relevant both to plant engineers specifying temperature control and to OEM and system integration requirements, where heat-trace manufacturers and system integrators incorporate electronic temperature control into wider equipment or heat-trace assemblies.

Kelvin is supplied as an ATEX/IECEx Ex component rather than a stand-alone finished enclosure. BHTC and BHTL configurations are certified for EPL Gb/Db applications, while BHTLC is certified for EPL Gc/Dc applications. The selected configuration must therefore be incorporated into suitable equipment or an enclosure and matched to the hazardous area, control function and installation requirements of the final application.

Key Features

  • Hazardous area certification: BHTC and BHTL are ATEX/IECEx Ex component-certified for EPL Gb/Db applications, while BHTLC is Ex component-certified for EPL Gc/Dc applications.
  • Trace-heating compliance: Controller, limiter and combined controller/limiter configurations meet the applicable IEC/IEEE 60079-30-1 requirements within their certified EPL scope.
  • Two-point control and fault response: Heater operation is controlled according to measured temperature, setpoint and hysteresis, with the heater de-energised if a sensor or device malfunction is detected.
  • Temperature limiter operation: Limiter configurations de-energise the heater when the limiting temperature is reached and require a manual reset before heating is restored.
  • Remote Modbus access: Modbus RTU configurations support remote parameter setting and monitoring of operating and device-status information.
  • Local Bluetooth access: Bluetooth-equipped configurations support local programming and monitoring without opening the final enclosure, subject to use of a suitable programming device for the hazardous area.
  • Diagnostic monitoring: Available status functions identify temperature warnings, sensor faults, relay-life warnings and device over-temperature conditions through the fitted interfaces.
  • Installation flexibility: DIN rail clip or panel mounting supports integration into the suitably protected enclosure required for the final installation.

Specifications

Models and Functions
Product SeriesBHTx Kelvin
BHTC FunctionTemperature controller
BHTL FunctionTemperature limiter
BHTLC FunctionCombined temperature controller and limiter
Number of CircuitsSingle circuit
Control MethodTwo-point control
Temperature Measurement and Control
Temperature Control Range0 to 500°C
Temperature Measurement Range-60 to 500°C
Temperature InputPt100 RTD
Measurement Accuracy±0.5% FS
Temperature Units°C / °F
Default Hysteresis5 K / 9°F
Power and Electrical
BHTC / BHTL Supply Voltage85 to 250 VAC; up to 277 VAC subject to relay-life limits
BHTLC Supply Voltage85 to 250 VAC
Rated Power Without Load4.5 W
Switching / Load CurrentUp to 30 A for BHTC/BHTL; BHTLC maximum 22 A, subject to certified thermal and electrical limits
Maximum Breaker Size32 A maximum, subject to applicable load limits
Optional Alarm Relay2 A resistive load at 250 VAC or 36 VDC; up to 277 VAC subject to relay-life limits
Configuration and Communications
Setpoint ConfigurationDial, Modbus or Bluetooth depending on configuration; configurations without a dial may use a factory-configured fixed setpoint
ModbusModbus RTU, 9600 baud, 8-N-1
BluetoothAvailable depending on configuration
LED Status IndicationAvailable depending on configuration
Installation and Environmental
MountingDIN rail clip or panel
Enclosure RequirementInstallation in a suitable enclosure providing at least IP65 protection in accordance with the certification schedule
UV ExposureKelvin must be installed so that it is not susceptible to UV light
Load DeratingAllowable load current depends on ambient/service temperature and permitted surface temperature
Hazardous Area and Compliance
Certification StatusEx component requiring incorporation into suitable equipment or an enclosure for use in explosive atmospheres
Trace-Heating StandardIEC/IEEE 60079-30-1 within the certified scope of the applicable configuration
IECEx CertificateIECEx DEK 19.0014U, Issue 2
BHTC / BHTL IECEx MarkingEx eb mb [ib] [60079-30-1] IIC Gb; [Ex ib 60079-30-1 Db] IIIC
BHTC / BHTL ATEX CertificateDEKRA 19ATEX0028U, Issue 2
BHTC / BHTL ATEX MarkingII 2 G Ex eb mb [ib] [60079-30-1] IIC Gb; II (2) D [Ex ib 60079-30-1 Db] IIIC
BHTLC IECEx MarkingEx eb mb [ib] [60079-30-1] IIC Gc; [Ex ib 60079-30-1 Dc] IIIC
BHTLC ATEX CertificateDEKRA 25ATEX0021U, Issue 0
BHTLC ATEX MarkingII 3 G Ex eb mb [ib] [60079-30-1] IIC Gc; II (3) D [Ex ib 60079-30-1 Dc] IIIC
North American DesignDesigned for Class I, Division 2

Support

Able Instruments is Barksdale’s Master Distributor in the UK and Ireland, providing application guidance, configuration support and technical assistance for Kelvin temperature-control requirements.

  • Application guidance: Selection support for controller, limiter or combined controller/limiter duties and the required hazardous area classification
  • Configuration support: Guidance on electrical load, alarm relay and dial, Modbus or Bluetooth options
  • Technical support: Pre-sales advice on enclosure requirements, certified operating limits and correct application of the Kelvin Ex component
  • OEM and system support: Assistance for heat-trace manufacturers and system integrators incorporating Kelvin into wider equipment or control assemblies
  • Barksdale Master Distributor in the UK and Ireland
  • UK technical support available
  • Application and configuration support
Summary
Contact

Prefer to speak to a Product Specialist? Call us on:
01189311188