AMETEK Brookfield Jerome 10:1 Dilution Module
10:1 dilution module for measuring high gas concentrations with Jerome analysers.
Key highlights
- High concentration measurement: Enables analysis of gas levels above the instrument range
- 10:1 dilution ratio: Reduces sample concentration using filtered fresh air
- Jerome compatibility: Designed for use with Jerome analysers including J405, J505 and J605
- Application limitation: Not suitable for low gas levels already within range
The AMETEK Brookfield Jerome 10:1 Dilution Module is an accessory designed for use with Jerome gas analysers where sampled gas concentrations exceed the instrument’s direct measurement capability. It connects inline with the analyser intake, enabling higher concentration samples to be processed safely within the measurement system.
It is used in applications where gas levels are expected to exceed the analyser’s normal operating range. By conditioning the sample before it reaches the instrument, the module allows measurements to be taken without overloading the sensor, supporting controlled monitoring of elevated mercury (Hg) or hydrogen sulphide (H₂S) concentrations.
The module operates by mixing a portion of the incoming sample with filtered fresh air before it enters the analyser. During sampling, gas is drawn through the module and diluted prior to measurement, meaning the value displayed by the instrument must be multiplied by ten to determine the actual gas level.
Important: The module must be used only where dilution is required, and the fresh air inlet must remain unobstructed to maintain correct operation during sampling.
Key Features
- Sampling path integration: Installs between the sample inlet and analyser intake as part of the measurement setup
- Controlled air mixing: Introduces filtered ambient air into the sample stream to achieve consistent dilution behaviour
- Measurement workflow adjustment: Requires interpretation of analyser readings as diluted values during operation
- Flexible inlet configuration: Sample inlet can be connected to ¼” rigid tubing where required for field or fixed setups
- Open air inlet requirement: Fresh air inlet must remain unrestricted to maintain stable dilution performance
Specifications
| Compatibility | |
| Compatible instruments | Jerome J405, J505 and J605 |
| Application gases | Mercury (Hg) or Hydrogen Sulphide (H₂S) |
| Accessory function | 10:1 sample dilution for high-concentration gas measurement |
| Physical | |
| Sample inlet | Suitable for connection to ¼” rigid tubing |
| Fresh air inlet | Barbed fitting, must remain unobstructed during use |
| Instrument connection | Outlet fitting inserts into Jerome instrument intake |
| Ordering | |
| Part number | 990-0225 |
| Options required | Specify Hg or H₂S when ordering |
Support
Need help confirming whether a dilution module is required for your application?
- Compatibility confirmation: Verify suitability for your Jerome analyser and monitoring setup
- Application guidance: Advice on when dilution is required based on expected gas concentration levels
- Configuration support: Assistance selecting the correct Hg or H₂S option for your measurement requirements