Dwyer Series 16B dual-loop temperature and process controller
Roll over image to zoom in
  • Official UK and Ireland channel partner
  • UK technical support available
  • Model selection and configuration support

Dwyer Series 16B Dual-Loop Temperature and Process Controller

Control temperature or analogue process variables with a compact 1/16 DIN controller, dual-output heat/cool control and standard RS-485.

Key highlights

  • Format: 1/16 DIN with two control outputs
  • Inputs: Thermocouple, RTD, voltage or current
  • Control: On/off, PID or manual
  • Programming: Up to 64 ramp/soak steps
  • Integration: RS-485 Modbus ASCII/RTU standard

The Dwyer Series 16B is a compact 1/16 DIN temperature and process controller with one universal measurement input and two hardware control outputs. DwyerOmega’s dual-loop arrangement assigns the outputs to heating and cooling around the same process value and setpoint; it is not a two-input controller.

The universal input can be configured for supported thermocouples, Pt100 or JPt100 RTDs, or compatible DC voltage and current signals. Dual four-digit LED displays show the process value and setpoint for clear local operation.

On/off, PID and manual output control cover common regulation duties. Automatic tuning supports PID setup, while the separate ramp/soak programme provides up to 64 steps for processes that require controlled setpoint changes over time.

Output hardware is selected with the model. Output 1 can be specified as a 14 VDC voltage-pulse, relay, 4-20 mA or 0-10 V output; output 2 is a relay in the standard model combinations. RS-485 with Modbus ASCII or RTU is standard, while the supply is selected as 100-240 VAC or 24 VDC.

The Series 16B suits ovens, boilers, chillers, environmental chambers, hot plates, melt pots, packaging equipment and compatible process-control duties. Selection should account for the input signal and range, heat/cool assignment, output hardware and load, alarm use, supply and panel installation.

Key Features

  • Universal input: Configure the controller for a supported thermocouple, RTD or analogue process signal
  • Dual-output heat/cool control: Assign outputs 1 and 2 to heating and cooling around one measured process value and setpoint
  • Control choices: Select on/off, PID or manual output control for the required regulation duty
  • PID tuning: An automatic tuning function helps establish PID parameters for the application
  • Ramp/soak programming: Build up to eight patterns of eight steps for a maximum of 64 programmed steps
  • Model-selected outputs: Match relay, 14 VDC voltage pulse, 4-20 mA or 0-10 V hardware to the interface and load
  • Alarm flexibility: Dedicated alarm relay, with output 2 available for an additional alarm function when not used for dual-output control
  • Standard communications: Integrate through RS-485 using Modbus ASCII or RTU

Specifications

Inputs and Measurement
Input typesUser-selectable thermocouple, RTD, DC voltage, DC current or millivolt signal
Thermocouple typesK, J, T, E, W, R, S, B, L and U
RTD typesPt100 and JPt100
Analogue inputs0-5 V, 0-10 V, 0-20 mA, 4-20 mA and 0-50 mV
Current-input requirementA-277 250 ohm precision resistor across the input terminals
Process-input display range-999 to 9999
Accuracy±0.25% of span ±1 least significant digit
Control and Programming
Control modesOn/off, PID or manual output control
PID tuningAutomatic tuning function for PID parameter setup
Dual-output controlOutputs 1 and 2 assignable to heating and cooling around one process value and setpoint
Ramp/soak programmeEight patterns with eight steps each; up to 64 steps
Alarm functionsOne dedicated alarm relay; output 2 can provide an additional alarm function when not assigned to dual-output control
MemoryNon-volatile configuration memory
Outputs and Communications
Output 1 choices14 VDC voltage pulse, relay, 4-20 mA current or 0-10 V linear voltage, according to model
Output 2 choicesRelay in the standard model combinations; confirm any alternative arrangement before selection
Control relaySPST; permitted load depends on the selected model and output position and must be confirmed before direct load switching
Voltage-pulse output14 VDC, 40 mA maximum
Current output4-20 mA; 600 ohm maximum load
Linear-voltage output0-10 V
Dedicated alarm relaySPST, 3 A at 250 VAC resistive
CommunicationsRS-485 with Modbus ASCII or RTU; standard on all models
Display and Power
DisplayTwo four-digit, seven-segment LED displays; process value red and setpoint green
Standard supply100-240 VAC, 50/60 Hz
Low-voltage supply24 VDC, selected by model
Power consumption5 VA maximum
Mechanical and Environmental
Panel format1/16 DIN, nominal 48 x 48 mm front
Panel cut-out45 x 45 mm, ±0.6 mm
Overall depthApproximately 80 mm
MountingEnclosed-panel mounting
Front-panel ratingIP56
Operating temperature0 to 50°C
Storage temperature-20 to 65°C
WeightApproximately 114 g
Compliance
ApprovalsCE and cULus

Support

Able Instruments are an official UK and Ireland channel partner for DwyerOmega, providing application advice, configuration support and quotation assistance for the Series 16B family.

  • Model selection: Support matching the input, output 1 and output 2 hardware, supply, alarm use and panel requirements
  • Option compatibility: Checks for heat/cool assignment, alarm use, RS-485 integration and relevant accessories
  • Installation support: Advice on sensor or transmitter input, output loading, panel mounting and front-panel protection
  • Documentation support: Help with the catalogue sheet, operating manual, configuration records and replacement requirements
  • Official UK and Ireland channel partner
  • UK technical support available
  • Model selection and configuration support

Accessories

  • A-277 250 ohm precision resistor for DC current inputs
  • A-600 R/C snubber for relay-controlled contactor or solenoid coils
  • MN-1 Mini-Node USB/RS-485 converter for the standard RS-485 interface
Summary
Contact

Prefer to speak to a Product Specialist? Call us on:
01189311188