Jerome J605 fixed hydrogen sulphide analyser in outdoor enclosure for continuous site monitoring
Roll over image to zoom in
  • Exclusive UK & Ireland Jerome partner
  • European Service Centre for Jerome analysers
  • System design support for fixed hydrogen sulphide monitoring
  • Guidance on portable and fixed Jerome deployment

AMETEK Brookfield Jerome J605 Fixed Monitoring Hydrogen Sulphide Analyser

Continuous hydrogen sulphide monitoring for odour, environmental, and industrial site applications.

Key highlights

  • Continuous H₂S monitoring: Provides automated, long-term measurement for odour control and environmental compliance.
  • Perimeter monitoring system: Designed for fenceline and site boundary deployment in outdoor environments.
  • Gold film sensor technology: Proven method for stable, repeatable low-level hydrogen sulphide measurement.
  • Outdoor-ready enclosure: IP-rated housing with temperature control for harsh conditions.
  • Scalable site coverage: Multiple units can be deployed for wider monitoring coverage.
  • Removable analyser capability: Enables portable surveys to identify emission sources and hotspots.

The AMETEK Brookfield Jerome J605 Fixed Hydrogen Sulphide Analyser is a complete system designed for continuous, unattended measurement of hydrogen sulphide in industrial and environmental applications.

It is typically used where ongoing monitoring of H₂S levels is required, particularly in odour control, wastewater treatment, and environmental compliance programmes. The system provides reliable measurement of low-level hydrogen sulphide concentrations, supporting both operational visibility and regulatory reporting.

The system is configured to suit the application, with enclosure design, sampling system, power supply, and communication outputs specified based on site requirements. This ensures the monitoring solution aligns with installation conditions, environmental exposure, and data integration needs.

The analyser is housed within a robust environmental enclosure, incorporating temperature control, local indication, and system outputs. This enables reliable outdoor deployment in exposed locations, with installation options including poles, walls, fences, or dedicated mounting structures.

Unlike portable instruments used for spot checks, this system is designed for continuous monitoring, automatically sampling at defined intervals and providing ongoing visibility of site conditions. Multiple units can be deployed across a site to support perimeter or fenceline monitoring strategies.

A key advantage is the removable analyser design, allowing the J605 unit to be used for portable surveys to identify emission sources or concentration hotspots. Once identified, the analyser can be returned to the enclosure for continuous monitoring and verification.

Key Features

  • Continuous automated monitoring: Configurable sampling intervals enable unattended operation for long-term hydrogen sulphide measurement.
  • Ultra-low level detection: Measures hydrogen sulphide at ppb levels, supporting sensitive environmental and odour monitoring applications.
  • Gold film sensor technology: Proven detection method delivering selective, stable, and repeatable H₂S measurement.
  • Environmental enclosure system: IP-rated GRP housing with internal temperature control for reliable outdoor deployment.
  • 4–20 mA output integration: Enables connection to site control systems, PLCs, and remote monitoring platforms.
  • Flexible installation options: Suitable for mounting on poles, fences, walls, or dedicated structures depending on site layout.
  • Removable analyser functionality: Allows portable use of the J605 unit for investigation and identification of emission sources.
  • Scalable monitoring approach: Multiple systems can be deployed across a site to support perimeter or fenceline monitoring strategies.
  • Optional data logging capability: Supports storage and reporting of measurement data when configured with appropriate logging systems.

Specifications

Measurement Performance
Detection Range3 ppb (0.003 ppm) to 10 ppm
Resolution20 ppt (0.02 ppb) *range dependent
Accuracy / PrecisionRange 0: ±1 ppb at 5 ppb / 10% RSD
Range 0: ±3 ppb at 50 ppb / 5% RSD
Range 1: ±0.03 ppm at 0.5 ppm / 5% RSD
Range 2: ±0.3 ppm at 5.0 ppm / 5% RSD
Response TimeSurvey Mode: 12-27 seconds
Manual Mode: 12-27 seconds
Auto Mode: 12-53 seconds
Flow Rate150 mL/min
Result Unitsppm, ppb
Sampling and Monitoring
Autosample Intervals1, 2, 5, 10, 15, 30, 45, 60, 90 or 120 minutes
Integrated Data Storage20,000 test results; retains date, time and up to 80 locations
Display8-digit alphanumeric LCD
OutputDigital: USB serial data to PC, printer or USB flash drive
Analog: 4-20 mA passive current loop; accurate to 0.3% of output
Environmental and Enclosure
Operating Environment-40°C to +55°C*
EnclosurePolyester glass-reinforced enclosure, IP66 rated
Internal Adjustable Thermostat(+5 to +60 °C) 10 Amp contact rating
Power and Electrical
BatteryRechargeable NiMH
18-hour life, charges in 3 hours
FuseAuto-resetting fuse
Mains Power Line Filter250VAC 50/60Hz @ 6Amps
Switch Mode PSU 1Output 24VDC, 5 Amps, 120 watt
Switch Mode PSU 2Output 12VDC, 1.5 Amps, 15 watt
Input Power Consumption (110VAC)2.5 Amp @ 220 watts (3.0 Amp fuse)
Input Power Consumption (240VAC)2.0 Amp @ 385 watts (2.5 Amp fuse)
Site Power Termination110V
Site Data Termination4-20 mA
System Configuration and Physical
System ComponentsJerome J605 analyser with comms capabilities
GRP IP66/7 enclosure
Illuminated local display
Electropolished SS sample inlet assembly (bottom entry)
Thermostatically controlled internal heater
Power supply module
Analyser mounting hardware
Universal backplate
Dimensions600 (H) x 400 (W) x 260 mm (D)
Weight (Loaded)12 kg approx.

Support

Able Instruments are the Exclusive UK & Ireland Partner for AMETEK Brookfield Jerome analysers, providing application advice, system configuration, and ongoing support for fixed hydrogen sulphide monitoring installations.

  • Application support: Guidance on monitoring strategy, including odour control, wastewater processes, and site-based hydrogen sulphide detection.
  • System configuration: Assistance specifying enclosure systems, outputs, and monitoring layouts for your application.
  • Installation and commissioning: Support with system setup, placement, and operational best practice.
  • Training and operation: Advice on effective use, including combining fixed monitoring with portable survey workflows.
  • Service and maintenance: Ongoing support including calibration, servicing, and system optimisation.
  • Exclusive UK & Ireland Jerome partner
  • European Service Centre for Jerome analysers
  • System design support for fixed hydrogen sulphide monitoring
  • Guidance on portable and fixed Jerome deployment

Other Hydrogen Sulphide Monitoring Options

Depending on whether you need portable survey capability rather than continuous fixed monitoring, this Jerome model may also be suitable.

AMETEK Brookfield Jerome J605 Hydrogen Sulphide Analyser

Best for: Portable hydrogen sulphide surveys and source detection

Designed for handheld use to locate and assess H₂S emission sources and concentration hotspots before or alongside fixed monitoring deployment.

Summary
Contact

Prefer to speak to a Product Specialist? Call us on:
01189311188